AD 2002-20-03 Airworthiness Directives; Eurocopter France Model AS332C, L, L1, and L2; AS350B, BA, B1, B2, B3, and D; AS355E, F, F1, F2, and N; AS-365N2; AS 365 N3; SA330F, G, and J; SA-360C; SA-365C, C1, and C2; SA.316B and C; and SA.319B Helicopters

2002-11-06
2002-10-02
39-12898
2000-SW-55-AD
Airframe
—

Applicability*9

Model AS332C, L, L1, and L2; AS350B, BA, B1, B2, B3, and D; AS355E, F, F1, F2, and N; AS-365N2; AS 365 N3; SA330F, G, and J; SA-360C; SA-365C, C1, and C2 helicopters with a metal ferry fuel tank (tank), part number (P/N) 330A 871310.00, .01, .02, .03, or .04, installed; and Model SA.316B and C; and SA.319B helicopters with a tank, P/N 3160S 7375020, or 3160S 7375020-1, installed, certificated in any category. Note 1: This AD applies to each helicopter identified in the preceding applicability provision, regardless of whether it has been otherwise modified, altered, or repaired in the area subject to the requirements of this AD. For helicopters that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.

Compliance

Required before the next refueling of an installed tank or before the first fueling after installing a tank, unless accomplished previously. To prevent refueling a tank that is not adequately electrically bonded, which could generate an electric arc between the refueling nozzle and the tank, causing a fuel tank explosion, accomplish the following: (a) Measure the electrical resistance between the tank electrostatic ground connector (item C) and the tank filler neck (item G) as shown in Figure 1 of this AD. If the value of the electrical resistance is more than 1.5 milliohms, refueling the tank is prohibited. See Figure 1 as follows: ER02OC02.004 Note 2: Eurocopter Telex No. 000112 dated June 6, 2000, pertains to the subject of this AD. (b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Regulations Group, Rotorcraft Directorate, FAA. Operators shall submit their requests through an FAA Principal Maintenance Inspector, who may concur or comment and then send it to the Manager, Regulations Group. Note 3: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Regulations Group. (c) Special flight permits will not be issued. (d) This amendment becomes effective on November 6, 2002. Note 4: The subject of this AD is addressed in Direction Generale De L'Aviation Civile (France) AD 2000-302(A), dated July 12, 2000. Issued in Fort Worth, Texas, on September 19, 2002. Eric D. Bries, Acting Manager, Rotorcraft Directorate, Aircraft Certification Service. [FR Doc. 02-24988 Filed 10-1-02; 8:45 am] BILLING CODE 4910-13-P

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1