Airworthiness directives › 2004-25-16
AD 2004-25-16 Airworthiness Directives; Kelly Aerospace Power Systems Part Number (P/N) 14D11, A14D11, B14D11, C14D11, 23D04, A23D04, B23D04, C23D04, or P23D04 Fuel Regulator Shutoff Valves (Formerly Owned by ElectroSystems, JanAero Devices, Janitrol, C&D Airmotive Products, FL Aerospace, and Midland-Ross Corporation)
Makes named: kelly aerospace. Read the applicability below — it usually turns on serial or part numbers too.
Applicability*9
(c) This AD applies to aircraft equipped with a fuel regulator shutoff valve part number (P/N) 14D11, A14D11, B14D11, C14D11, 23D04, A23D04, B23D04, C23D04, or P23D04 used with B1500, B2030, B2500, B3040, B3500, B4050, or B4500 B-Series combustion heaters. The following is a list of aircraft where the B-Series combustion heater could be installed. This is not a comprehensive list and aircraft not on this list that have the heater installed through field approval or other methods are still affected by this AD: Manufacturer Aircraft models/series (1) Bombardier Inc CL-215, CL-215T, and CLT-415. (2) Cessna Aircraft Company 208, T303, 310F, 310G, 310H, 310I, 310J, 310K, 310L, 310N, 310P, 310Q, 320C, 320D, 320E, 320F, 337 Series, 340, 340A, 414, 414A, 421, 421A, 421B, and 421C. (3) The New Piper Aircraft Inc PA-23 Series, PA-30, PA-31 Series, PA-34 Series, PA-39, and PA-44 Series. (4) Raytheon Aircraft Corporation 95-B55 Series, 58, 58TC, 58P, 60, A60, and 76. Note 1: The B1500, B2030, B2500, B3040, B3500, B4050, or B4500 B-Series combustion heaters were previously manufactured by Janitrol, C&D Airmotive Products, FL Aerospace, and Midland-Ross Corporation.
Required actions
(e) To address this problem, you must do the following: Actions Compliance Procedures (1) Visually inspect or pressure test the fuel regulator shutoff valve for any signs of fuel leaks Within the next 25 hours aircraft time-in-service (TIS) after January 5, 2005, (the effective date of AD 2004-25-16), unless already done within the last 75 hours aircraft TIS ( e.g., compliance with AD 2001-08-01 or 2001-17-13). Repetitively inspect thereafter at intervals not to exceed 100 hours aircraft TIS or 12 months, whichever occurs first. This is established to coincide with 100-hour and annual with 100-hour and annual inspections Locate the pressure shutoff valve in the installation using the applicable maintenance manual for valve location, removal, and installation instructions. Follow the procedures in Kelly Aerospace Power Systems Service Bulletin No. A-107A, Issue Date: September 6, 2002, for the visual inspection or the pressure test. (2) If no fuel leaks or no signs of fuel stains are found during each inspection required by paragraph (e)(1) of this AD, make a log book entry with the date of inspection (month/year) Prior to further flight after each inspection required in paragraph (e)(1) of this AD Follow the procedures in Kelly Aerospace Power Systems Service Bulletin No. A-107A, Issue Date: September 6, 2002. (3) If any signs of fuel leaks or any signs of fuel stains are found during any inspection required in paragraph (e)(1) of this AD, replace the valve with a new valve of appropriate part number (P/N) that has a manufacturer's date code of 02/02 or later. For Piper PA-31-350 model aircraft, replace P/N A23D04-7.5 valve with P/N P23D04-7.5 Ensure there are no fuel leaks in the replacement valve by following the inspection and documentation requirements in paragraphs (e)(1) and (e)(2) of this AD Before further flight after the inspection where any fuel leak was found Follow Kelly Aerospace Power Systems Service Bulletin No. A-107A, Issue Date: September 6, 2002; Piper Vendor Service Publication VSP-150, dated January 31, 2003; and the applicable maintenance manual. (4) As an alternative method of compliance to this AD, you may disable the heater provided you immediately comply with inspection, identification, and replacement requirements of this AD when you bring the heater back into service. Do the following actions when disabling: (i) Cap the fuel supply line upstream of the fuel regulator and shutoff valve; If you choose this option, you must do it before the next required inspection specified in paragraph (e)(1) of this AD. To bring the heater back into service, you must do the actions of paragraphs (e)(1), (e)(2), and (e)(3) of this AD (inspection, identification, and replacement, as necessary) Not Applicable. (ii) Disconnect the electrical power and ensure that the connections are properly secured to reduce the possibility of electrical spark or structural damage; (iii) Inspect and test to ensure that the cabin heater system is disabled; (iv) Ensure that no other aircraft system is affected by this action; (v) Ensure there are no fuel leaks; and (vi) Fabricate a placard with the words: “System Inoperative”. Install this placard at the heater control valve within the pilot's clear view (5) Only install a fuel regulator shutoff valve with a manufacture date code of 02/02 or later As of January 5, 2005, (the effective date of AD 2004-25-16) Not Applicable.
Unsafe condition
(d) This AD is the result of numerous reports of fuel regulator shutoff valves leaking fuel. We are issuing this AD to prevent failure of the fuel regulator shutoff valve, which could result in fuel leakage in aircraft with these combustion heaters. This failure could result in an aircraft fire.
Affected ADs
(b) This AD revises AD 2004-25-16, Amendment 39-13904.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1