Airworthiness directives › 2005-08-08
AD 2005-08-08 Airworthiness Directives; McDonnell Douglas Model DC-8-33 and -43 Airplanes; Model DC-8F-54 and DC-8F-55 Airplanes; and Model DC-8-50, -60, -60F, -70, and -70F Series Airplanes
Applicability*9
This AD applies to McDonnell Douglas Model DC-8-33, DC-8-43, DC-8-51, DC-8-52, DC-8-53, DC-8F-54, DC-8-55, DC-8F-55, DC-8-61, DC-8-61F, DC-8-62, DC-8-62F, DC-8-63, DC-8-63F, DC-8-71, DC-8-71F, DC-8-72, DC-8-72F, DC-8-73, and DC-8-73F airplanes; certificated in any category; as identified in Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003.
Compliance
You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Restatement of Requirements of AD 2001-25-01 Repetitive Inspections and Tests, and Corrective Action(s), if Necessary (f) Within 30 days after December 20, 2001 (the effective date of AD 2001-25-01, amendment 39-12553), do the action(s) specified in paragraphs (f)(1) and (f)(2) of this AD, in accordance with Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001. (1) Do an inspection of the electrical connectors of the explosive cartridge wiring of the engine fire extinguisher containers to verify if the identification number labels are installed and legible. If any identification number label is missing or is not legible, before further flight, install a label or replace the label with a new label, as applicable. Repeat the inspection after each maintenance action for the Firex Discharge system. (2) Do an electrical test of all explosive cartridge wiring of the engine fire extinguisher containers to verify proper installation and function, using the cockpit warning lamps. If the lamp fails to illuminate, before further flight, troubleshoot and repair the wiring of the Firex Discharge system. Repeat the test after each maintenance action for the Firex Discharge system. Note 1: Inspections, tests, and corrective actions, if necessary, done per Boeing BOECOM M-7200-01-02632, dated November 5, 2001, before December 20, 2001 (the effective date of AD 2001-25-01, amendment 39-12553), are considered acceptable for compliance with the requirements of paragraph (f) of this AD. New Requirements of This AD Inspection and Installation (g) Within 18 months of the effective date of this AD, do a general visual inspection of the emergency shut off wire assembly to determine if the length of wire harness AAG at P1-510 can be connected to R5-74 and to determine if the length of wire harness ABG at P1-511 can be connected to R5-73; and, before further flight, do the corrective action, as applicable; by accomplishing all of the actions specified in paragraph B.1.b. of the Accomplishment Instructions of Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003. Note 2: For the purposes of this AD, a general visual inspection is defined as: “A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked.” (h) Within 18 months of the effective date of this AD, install lanyards on the electrical connectors for the engine fire extinguishing agent containers in the left and right wing front spar; and, before further flight, do all the related investigative/corrective actions, as applicable; by accomplishing all of the actions specified in paragraph B.1.c. of the Accomplishment Instructions of Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003. Installation if Applicable (i) For airplanes equipped with an auxiliary power unit (APU) installation in the forward cargo compartment at station Y=640.000: Within 18 months of the effective date of this AD, install lanyards on the electrical connectors for the APU fire extinguishing agent containers; and, before further flight, do all the related investigative/corrective actions, as applicable; by accomplishing all of the actions specified in paragraph B.2. of the Accomplishment Instructions of Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003. Terminating Action (j) Accomplishment of the actions specified in paragraphs (g) and (h) of this AD terminates the repetitive inspections and electrical tests required by paragraph (f) of this AD. Credit for Previous Service Bulletin (k) Actions done before the effective date of this AD in accordance with Boeing Service Bulletin DC8-26-047, dated April 2, 2003, are acceptable for compliance with the corresponding requirements in paragraphs (g), (h), and (i) of this AD. Alternative Methods of Compliance (AMOCs) (l) The Manager, Los Angeles Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. Material Incorporated by Reference (m) You must use Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003; and Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001; as applicable; to perform the actions that are required by this AD, unless the AD specifies otherwise. (1) The incorporation by reference of Boeing Service Bulletin DC8-26-047, Revision 1, dated September 4, 2003, is approved by the Director of the Federal Register, in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (2) The incorporation by reference of Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001, was approved previously by the Director of the Federal Register as of December 20, 2001 (66 FR 63157, December 5, 2001). (3) To get copies of the service information, contact Boeing Commercial Airplanes, Long Beach Division, 3855 Lakewood Boulevard, Long Beach, California 90846, Attention: Data and Service Management, Dept. C1-L5A (D800-0024. To view the AD docket, go to the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street SW., room PL-401, Nassif Building, Washington, DC. To review copies of the service information, go to the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Issued in Renton, Washington, on April 11, 2005. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. 05-7684 Filed 4-20-05; 8:45 am] BILLING CODE 4910-13-P
Unsafe condition
This AD was prompted by reports of cross-wired electrical connectors of the engine fire extinguishing agent containers. We are issuing this AD to detect and correct cross-wired electrical connectors of the fire extinguishing system, which could release fire extinguishing agent into the incorrect engine nacelle in the event of an engine fire.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1