Airworthiness directives › 2006-09-08
AD 2006-09-08 Airworthiness Directives; Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) Airplanes
Applicability*9
This AD applies to Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, serial numbers 7003 through 7990 inclusive and 8000 and subsequent; certificated in any category.
Compliance
You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Modification (f) Within 90 days after the effective date of this AD, modify the wiring on AC service bus contactor K4XA, in accordance with the Accomplishment Instructions of Bombardier Alert Service Bulletin A601R-24-121, dated April 18, 2006. Previous Actions Accomplished According to Modification Package (g) Actions accomplished before the effective date of this AD according to Bombardier Modification Summary Package IS601R2450-0025, dated December 23, 2005, are considered acceptable for compliance with the action specified in paragraph (f) of this AD. Alternative Methods of Compliance (AMOCs) (h)(1) The Manager, New York Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) Before using any AMOC approved in accordance with § 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office. Related Information (i) Canadian airworthiness directive CF-2006-07, dated April 19, 2006, also addresses the subject of this AD. Material Incorporated by Reference (j) You must use Bombardier Alert Service Bulletin A601R-24-121, dated April 18, 2006, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Room PL-401, Nassif Building, Washington, DC; on the Internet at http://dms.dot.gov ; or at the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code _of_federal_regulations/ibr_locations.html . Issued in Renton, Washington, on April 21, 2006. Kalene C. Yanamura, Acting Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. 06-3990 Filed 4-25-06; 8:45 am] BILLING CODE 4910-13-P
Unsafe condition
This AD results from incidents of short circuit failures of certain alternating current (AC) contactors located in the avionics bay. We are issuing this AD to prevent short circuit failures of certain AC contactors, which could result in arcing and consequent smoke or fire.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1