Airworthiness directives › 2006-11-07
AD 2006-11-07 Airworthiness Directives; Raytheon Model Hawker 800XP Airplanes
Makes named: raytheon. Models named: Hawker 800XP. Read the applicability below — it usually turns on serial or part numbers too.
Applicability*9
This AD applies to Raytheon Model Hawker 800XP airplanes, certificated in any category; serial numbers 258541, 258556, 258567 through 258609 inclusive, 258611 through 258628 inclusive, 258630 through 258684 inclusive, and 258686 through 258728 inclusive.
Compliance
You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Inspection/Corrective Action (f) Within 30 days after the effective date of this AD: Do a detailed inspection of the four bus bars in the DA-A panel to ensure that the bus bars match the panel configuration and clearance is adequate between the bus bars and adjacent components, by doing all the actions in accordance with the Accomplishment Instructions of Raytheon Service Bulletin SB 24-3745, Revision 1, dated September 2005. Accomplish any applicable corrective action before further flight in accordance with the service bulletin. Note 1: For the purposes of this AD, a detailed inspection is: “An intensive examination of a specific item, installation, or assembly to detect damage, failure, or irregularity. Available lighting is normally supplemented with a direct source of good lighting at an intensity deemed appropriate. Inspection aids such as mirror, magnifying lenses, etc., may be necessary. Surface cleaning and elaborate procedures may be required.” Note 2: A note in the Accomplishment Instructions of the Raytheon service bulletin instructs operators to contact Raytheon if any difficulty is encountered in accomplishing the service bulletin. However, any deviation from the instructions provided in the service bulletin must be approved as an alternative method of compliance (AMOC) under paragraph (i)(1) of this AD. Inspections Accomplished According to Previous Issue of Service Bulletin (g) Inspections accomplished before the effective date of this AD in accordance with Raytheon Service Bulletin SB 24-3745, dated September 2005, are considered acceptable for compliance with the inspections specified in paragraph (f) of this AD. No Reporting Requirement (h) Although the Accomplishment Instructions of Raytheon Service Bulletin SB 24-3745, Revision 1, dated September 2005, specify submitting certain information to the manufacturer, this AD does not include that requirement. Alternative Methods of Compliance (AMOCs) (i)(1) The Manager, Wichita Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) Before using any AMOC approved in accordance with § 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office. Material Incorporated by Reference (j) You must use Raytheon Service Bulletin SB 24-3745, Revision 1, dated September 2005, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas 67201-0085, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Room PL-401, Nassif Building, Washington, DC; on the Internet at http://dms.dot.gov; or at the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Issued in Renton, Washington, on May 15, 2006. Kevin M. Mullin, Acting Manager, , Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. 06-4801 Filed 5-24-06; 8:45 am] BILLING CODE 4910-13-P
Unsafe condition
This AD results from two reports of inadequate clearance between the bus bars in the DA-A panel. We are issuing this AD to prevent insufficient electrical isolation for the electrical bus configuration and inability of the flightcrew to isolate the bus bars in an emergency situation involving a dual generator failure, which could result in extra loads on the main ship batteries and consequent loss of power to the main essential bus.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1