Airworthiness directives › 2007-13-02
AD 2007-13-02 Airworthiness Directives; McDonnell Douglas Model DC-8-62, DC-8-62F, DC-8-63, DC-8-63F, DC-8-72, DC-8-72F, and DC-8-73F Airplanes
Models named: DC-8-62, DC-8-62F, DC-8-63, DC-8-63F, DC-8-72, DC-8-72F, DC-8-73F. Read the applicability below — it usually turns on serial or part numbers too.
Applicability*9
This AD applies to all McDonnell Douglas Model DC-8-62, DC-8-62F, DC-8-63, DC-8-63F, DC-8-72, DC-8-72F, and DC-8-73F airplanes, certificated in any category.
Compliance
You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Deactivation (f) Within 24 months after the effective date of this AD, deactivate the sump heater, scavenge valve, and scavenge pump of the center wing fuel tank, in accordance with the Accomplishment Instructions of Boeing Alert Service Bulletin DC8-28A089, dated November 1, 2006. Alternative Methods of Compliance (AMOCs) (g)(1) The Manager, Los Angeles Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) To request a different method of compliance or a different compliance time for this AD, follow the procedures in 14 CFR 39.19. Before using any approved AMOC on any airplane to which the AMOC applies, notify your appropriate principal inspector (PI) in the FAA Flight Standards District Office (FSDO), or lacking a PI, your local FSDO. Material Incorporated by Reference (h) You must use Boeing Alert Service Bulletin DC8-28A089, dated November 1, 2006, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Boeing Commercial Airplanes, Long Beach Division, 3855 Lakewood Boulevard, Long Beach, California 90846, Attention: Data and Service Management, Dept. C1-L5A (D800-0024), for a copy of this service information. You may review copies at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html. Issued in Renton, Washington, on June 8, 2007. Stephen P. Boyd, Acting Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. E7-11670 Filed 6-19-07; 8:45 am] BILLING CODE 4910-13-P
Unsafe condition
This AD results from fuel system reviews conducted by the manufacturer. We are issuing this AD to prevent certain conditions related to the sump heater, scavenge valve, and scavenge pump of the center wing fuel tank, which could lead to a possible ignition source in the fuel tank and a potential fire or explosion.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1