AD 2008-06-01 Airworthiness Directives; Bombardier Model CL-600-2C10 (Regional Jet Series 700, 701, & 702), Model CL-600-2D15 (Regional Jet Series 705), and CL-600-2D24 (Regional Jet Series 900) Airplanes

2008-04-16
2008-03-12
—
—
Airframe
—

Applicability*9

This AD applies to all Bombardier Model CL-600-2C10 (Regional Jet Series 700, 701, & 702), Model CL-600-2D15 (Regional Jet Series 705), and CL-600-2D24 (Regional Jet Series 900) airplanes, certificated in any category, all serial numbers. Note 1: This AD requires revisions to certain operator maintenance documents to include new inspections. Compliance with these inspections is required by 14 CFR 91.403(c). For airplanes that have been previously modified, altered, or repaired in the areas addressed by these inspections, the operator may not be able to accomplish the inspections described in the revisions. In this situation, to comply with 14 CFR 91.403(c), the operator must request approval for an alternative method of compliance according to paragraph (g)(1) of this AD. The request should include a description of changes to the required inspections that will ensure the continued operational safety of the airplane.

Compliance

Unless already done, do the following actions. (1) Within 60 days after the effective date of this AD, or on or before December 16, 2008, whichever occurs first, revise the ALS of the Instructions for Continued Airworthiness to incorporate the inspection requirements Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007 (“the MRM”). For task numbers 24-90-00-601, 24-90-00-602, 28-00-00-601, 28-11-23-601, 28-11-23-602, 28-12-13-601, 29-30-00-601, and 29-30-00-602, the initial compliance times start from the later of the times specified in paragraphs (f)(1)(i) and (f)(1)(ii) of this AD, and the repetitive inspections must be accomplished thereafter at the interval specified in the MRM, except as provided by paragraphs (f)(1) and (g)(1) of this AD. Accomplishing the revision in accordance with a later revision of the MRM is an acceptable method of compliance if the revision is approved by the Manager, New York Aircraft Certification Office (ACO), FAA, or Transport Canada Civil Aviation (TCCA) (or its delegated agent). (i) The effective date of this AD. (ii) The date of issuance of the original Canadian standard airworthiness certificate or the date of issuance of the original Canadian export certificate of airworthiness. (2) After accomplishing the actions specified in paragraph (f)(1) of this AD, no alternative inspections or inspection intervals may be used, unless the inspection or interval is part of a later revision of the Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007, that is approved by the Manager, New York ACO, FAA, or TCCA (or its delegated agent); or unless the inspection or interval is approved as an alternative method of compliance (AMOC) in accordance with the procedures specified in paragraph (g)(1) of this AD. FAA AD Differences Note 2: This AD differs from the MCAI and/or service information as follows: No differences. Other FAA AD Provisions (g) The following provisions also apply to this AD: (1) Alternative Methods of Compliance (AMOCs): The Manager, New York Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. Send information to Attn: Rocco Viselli, Aerospace Engineer, Airframe and Propulsion Branch, ANE-171, FAA, New York Aircraft Certification Office, 1600 Stewart Avenue, Suite 410, Westbury, New York 11590; telephone (516) 228-7331; fax (516) 794-5531. Before using any approved AMOC on any airplane to which the AMOC applies, notify your appropriate principal inspector (PI) in the FAA Flight Standards District Office (FSDO), or lacking a PI, your local FSDO. (2) Airworthy Product: For any requirement in this AD to obtain corrective actions from a manufacturer or other source, use these actions if they are FAA-approved. Corrective actions are considered FAA-approved if they are approved by the State of Design Authority (or their delegated agent). You are required to assure the product is airworthy before it is returned to service. (3) Reporting Requirements: For any reporting requirement in this AD, under the provisions of the Paperwork Reduction Act, the Office of Management and Budget (OMB) has approved the information collection requirements and has assigned OMB Control Number 2120-0056. Related Information (h) Refer to MCAI Canadian Airworthiness Directive CF-2007-28, dated November 22, 2007; and Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007; for related information. Material Incorporated by Reference (i) You must use Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007, to do the actions required by this AD, unless the AD specifies otherwise. (1) The Director of the Federal Register approved the incorporation by reference of this service information under 5 U.S.C. 552(a) and 1 CFR part 51. (2) For service information identified in this AD, contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, Station Centre-ville, Montreal, Quebec H3C 3G9, Canada. (3) You may review copies at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call (202) 741-6030, or go to: http://wwws.archives.gov/federal-register/cfr/ibr-locations.html . Issued in Renton, Washington, on February 28, 2008. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. E8-4494 Filed 3-11-08; 8:45 am] BILLING CODE 4910-13-P

Required actions

Unless already done, do the following actions. (1) Within 60 days after the effective date of this AD, or on or before December 16, 2008, whichever occurs first, revise the ALS of the Instructions for Continued Airworthiness to incorporate the inspection requirements Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007 (“the MRM”). For task numbers 24-90-00-601, 24-90-00-602, 28-00-00-601, 28-11-23-601, 28-11-23-602, 28-12-13-601, 29-30-00-601, and 29-30-00-602, the initial compliance times start from the later of the times specified in paragraphs (f)(1)(i) and (f)(1)(ii) of this AD, and the repetitive inspections must be accomplished thereafter at the interval specified in the MRM, except as provided by paragraphs (f)(1) and (g)(1) of this AD. Accomplishing the revision in accordance with a later revision of the MRM is an acceptable method of compliance if the revision is approved by the Manager, New York Aircraft Certification Office (ACO), FAA, or Transport Canada Civil Aviation (TCCA) (or its delegated agent). (i) The effective date of this AD. (ii) The date of issuance of the original Canadian standard airworthiness certificate or the date of issuance of the original Canadian export certificate of airworthiness. (2) After accomplishing the actions specified in paragraph (f)(1) of this AD, no alternative inspections or inspection intervals may be used, unless the inspection or interval is part of a later revision of the Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007, that is approved by the Manager, New York ACO, FAA, or TCCA (or its delegated agent); or unless the inspection or interval is approved as an alternative method of compliance (AMOC) in accordance with the procedures specified in paragraph (g)(1) of this AD. FAA AD Differences Note 2: This AD differs from the MCAI and/or service information as follows: No differences. Other FAA AD Provisions (g) The following provisions also apply to this AD: (1) Alternative Methods of Compliance (AMOCs): The Manager, New York Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. Send information to Attn: Rocco Viselli, Aerospace Engineer, Airframe and Propulsion Branch, ANE-171, FAA, New York Aircraft Certification Office, 1600 Stewart Avenue, Suite 410, Westbury, New York 11590; telephone (516) 228-7331; fax (516) 794-5531. Before using any approved AMOC on any airplane to which the AMOC applies, notify your appropriate principal inspector (PI) in the FAA Flight Standards District Office (FSDO), or lacking a PI, your local FSDO. (2) Airworthy Product: For any requirement in this AD to obtain corrective actions from a manufacturer or other source, use these actions if they are FAA-approved. Corrective actions are considered FAA-approved if they are approved by the State of Design Authority (or their delegated agent). You are required to assure the product is airworthy before it is returned to service. (3) Reporting Requirements: For any reporting requirement in this AD, under the provisions of the Paperwork Reduction Act, the Office of Management and Budget (OMB) has approved the information collection requirements and has assigned OMB Control Number 2120-0056. Related Information (h) Refer to MCAI Canadian Airworthiness Directive CF-2007-28, dated November 22, 2007; and Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007; for related information. Material Incorporated by Reference (i) You must use Section 3, “Fuel System Limitations,” of Part 2 of Bombardier CL-600-2C10, CL-600-2D15, and CL-600-2D24 Maintenance Requirements Manual CSP B-053, Revision 9, dated July 20, 2007, to do the actions required by this AD, unless the AD specifies otherwise. (1) The Director of the Federal Register approved the incorporation by reference of this service information under 5 U.S.C. 552(a) and 1 CFR part 51. (2) For service information identified in this AD, contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, Station Centre-ville, Montreal, Quebec H3C 3G9, Canada. (3) You may review copies at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, Washington; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call (202) 741-6030, or go to: http://wwws.archives.gov/federal-register/cfr/ibr-locations.html . Issued in Renton, Washington, on February 28, 2008. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. E8-4494 Filed 3-11-08; 8:45 am] BILLING CODE 4910-13-P

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1