TrackAD

Airworthiness directives › 2010-17-05

AD 2010-17-05 Airworthiness Directives; The Boeing Company Model 737-600, -700, -700C, -800, and -900 Series Airplanes

2010-09-22
2010-08-18
—
—
Airframe
—

Models named: 737-600, -700, -700C, -800, -900 series. Read the applicability below — it usually turns on serial or part numbers too.

Applicability*9

This AD applies to The Boeing Company Model 737-600, -700, -700C, -800, and -900 series airplanes, certificated in any category; as identified in Boeing Alert Service Bulletin 737-28A1201, Revision 1, dated May 28, 2009.

Compliance

Comply with this AD within the compliance times specified, unless already done. Replacement or Installation (f) Within 60 months after the effective date of this AD, do the actions required in paragraph (f)(1) or (f)(2) of this AD. (1) Replace the power control relays that are located in the R18, R19, R20, R21, R54, and R55 positions in the P91 and P92 power distribution panels for the fuel boost and override pumps with new, improved relays, part number KDAG-X4F-001, having a ground fault interrupter (GFI) feature, in accordance with the Accomplishment Instructions of Boeing Alert Service Bulletin 737-28A1201, Revision 1, dated May 28, 2009. (2) Install and maintain TDG Aerospace universal fault interrupters (UFIs) using Supplemental Type Certificate ST02079LA. Note 1: Boeing Alert Service Bulletin 737-28A1201, Revision 1, dated May 28, 2009, refers to Honeywell Service Bulletin 1151932-24-61 and Honeywell Service Bulletin 1151934-24-62, both Revision 5, both dated May 25, 2009, as additional sources of guidance for replacement of the power control relays in the P91 and P92 power distribution panels. (g) Actions done before the effective date of this AD in accordance with Boeing Alert Service Bulletin 737-28A1201, dated February 19, 2007, are acceptable for compliance with the requirements of paragraph (f) of this AD, provided that Revision 5 of Honeywell Service Bulletins 1151932-24-61 and 1151934-24-62, both dated May 25, 2009, are used as additional sources of guidance. Alternative Methods of Compliance (AMOCs) (h)(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. Send information to ATTN: Georgios Roussos, Aerospace Engineer, Systems and Equipment Branch, ANM-130S, 1601 Lind Avenue, SW., Renton, Washington 98057-3356; telephone (425) 917-6482; fax (425) 917-6590. Or, e-mail information to 9-ANM-Seattle-ACO-AMOC-Requests@faa.gov . (2) To request a different method of compliance or a different compliance time for this AD, follow the procedures in 14 CFR 39.19. Before using any approved AMOC on any airplane to which the AMOC applies, notify your principal maintenance inspector (PMI) or principal avionics inspector (PAI), as appropriate, or lacking a principal inspector, your local Flight Standards District Office. The AMOC approval letter must specifically reference this AD. Material Incorporated by Reference (i) You must use Boeing Alert Service Bulletin 737-28A1201, Revision 1, dated May 28, 2009, to do the actions required by this AD, unless the AD specifies otherwise. (1) The Director of the Federal Register approved the incorporation by reference of this service information under 5 U.S.C. 552(a) and 1 CFR part 51. (2) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; e-mail me.boecom@boeing.com ; Internet https://www.myboeingfleet.com . (3) You may review copies of the service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington. For information on the availability of this material at the FAA, call 425-227-1221. (4) You may also review copies of the service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Issued in Renton, Washington, on July 27, 2010. Ali Bahrami, Manager, Transport Airplane Directorate, Aircraft Certification Service. [FR Doc. 2010-19696 Filed 8-17-10; 8:45 am] BILLING CODE 4910-13-P

Unsafe condition

This AD results from fuel system reviews conducted by the manufacturer. We are issuing this AD to prevent pump housing burn-through due to electrical arcing, which could create a potential ignition source inside a fuel tank. This condition, in combination with flammable fuel vapors, could result in a fuel tank explosion and consequent loss of the airplane.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1