AD 2012-06-04 Airworthiness Directives; Bombardier, Inc. Airplanes

2012-04-25
2012-03-21
—
—
Airframe
—

Models named: DHC-8-400, -401, -402. Read the applicability below — it usually turns on serial or part numbers too.

Applicability*9

This AD applies to Bombardier, Inc. Model DHC-8-400, -401, and -402 airplanes; certificated in any category; serial numbers 4161 through 4296 inclusive.

Compliance

You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done.

Required actions

Within 600 flight hours after the effective date of this AD, do a general visual inspection of the structure and gearbox drain paths for blockages by sealant, in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 84-53-48, dated December 2, 2010. If any blockages are found, before further flight, remove blockages, in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 84-53-48, dated December 2, 2010.

Unsafe condition

This AD was prompted by reports of difficulties in opening the airstair door. We are issuing this AD to detect and correct drain paths blocked by sealant, resulting in an airstair door that is unable to be opened, which could hinder evacuation in the event of an emergency.

Affected ADs

None.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1