TrackAD

Airworthiness directives › 2012-16-03

AD 2012-16-03 Airworthiness Directives; HPH s. r.o. Sailplanes

2012-09-12
2012-08-08
—
—
Appliance
—

Applicability*9

This AD applies to HPH s. r.o. Models 304C, 304CZ, and 304CZ-17 sailplanes, all serial numbers, certificated in any category.

Compliance

Unless already done, do the following actions in accordance with HPH spol. s. r.o. Service Bulletin No.: G304CZ—06 a)_R01, G304C—06 a)_R01, G304CZ17—06 a)_R01, dated April 23, 2012: (1) Within 30 days after September 12, 2012 (the effective date of this AD), inspect the elevator control rod in the vertical fin. (2) If you find any deficiency during the inspection required by paragraph (f)(1) of this AD, before further flight, replace the elevator control rod with an elevator control rod that has a drain hole. (3) Within 9 months after September 12, 2012 (the effective date of this AD), unless already done as required by paragraph (f)(2) of this AD, replace the elevator control rod in the vertical fin with an elevator control rod that has a drain hole. (4) As of September 12, 2012 (the effective date of this AD), do not install an elevator control rod without a drainage hole.

Required actions

(1) You must use HPH spol. s. r.o. Service Bulletin No.: G304CZ—06 a)_R01, G304C—06 a)_R01, G304CZ17—06 a)_R01, dated April 23, 2012, to do the actions required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference (IBR) under 5 U.S.C. 552(a) and 1 CFR part 51. (2) For service information identified in this AD, contact HPH spol. s. r.o., Čáslavská 126, P.O. Box 112, 284 01 Kutná Hora, Czech Republic, telephone: +420 327 512 633; fax: +420 327 513 441; email: hph@hph.cz; Internet: www.hph.cz . (3) You may review copies of the service information at the FAA, FAA, Small Airplane Directorate, 901 Locust, Kansas City, Missouri 64106. For information on the availability of this material at the FAA, call (816) 329-4148. (4) You may also review copies of the service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at an NARA facility, call 202-741-6030, or go to http://www.archives.gov/federal-register/cfr/index.html . Issued in Kansas City, Missouri, on July 30, 2012. Earl Lawrence, Manager, Small Airplane Directorate, Aircraft Certification Service. [FR Doc. 2012-19094 Filed 8-7-12; 8:45 am] BILLING CODE 4910-13-P

Unsafe condition

This AD was prompted by mandatory continuing airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct an unsafe condition on an aviation product. The MCAI describes the unsafe condition as the lack of a drain hole in the elevator control rod, which may allow water to accumulate in the control rod and lead to possible corrosion. We are issuing this AD to prevent failure of the elevator control rod, which could result in loss of control of the sailplane.

Affected ADs

None.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1