Airworthiness directives › 2013-24-17
AD 2013-24-17 Airworthiness Directives; General Electric Company Turbofan Engines
Applicability*9
This AD applies to General Electric Company (GE) GE90-110B1 and GE90-115B turbofan engines with high pressure compressor (HPC) rotor stage 2-5 spools, part numbers (P/Ns) 351-103-106-0, 351-103-107-0, 351-103-141-0, 351-103-142-0, 351-103-144-0, 351-103-145-0, 351-103-148-0, 351-103-149-0, and 351-103-151-0, with spool serial numbers listed in paragraph 4, Appendix A of GE Service Bulletin (SB) No. GE90-100 S/B 72-0499, dated August 14, 2013.
Compliance
Remove from service HPC rotor stage 2-5 spools with serial numbers listed in paragraph 4, Appendix A of GE SB No. GE90-100 S/B 72-0499, dated August 14, 2013, as follows: (1) For spools with fewer than 4,500 cycles since new (CSN) on the effective date of this AD, before exceeding 5,000 CSN. (2) For spools with 4,500 CSN or more but fewer than 5,200 CSN on the effective date of this AD, within an additional 500 cycles in service (CIS) after the effective date of this AD but not to exceed 5,500 CSN. (3) For spools with 5,200 CSN or more but fewer than 5,600 CSN on the effective date of this AD, within an additional 300 CIS after the effective date of this AD but not to exceed 5,800 CSN. (4) For spools with 5,600 CSN or more but fewer than 5,800 CSN on the effective date of this AD, within an additional 200 CIS after the effective date of this AD but not to exceed 5,850 CSN. (5) For spools with 5,800 CSN or more but fewer than 6,000 CSN on the effective date of this AD, within an additional 50 CIS after the effective date of this AD but not to exceed 6,000 CSN. (6) For spools with 6,000 CSN or more on the effective date of this AD, before the next flight. (7) For spools that are not installed on the effective date of this AD and are subsequently installed onto any engine after the effective date of this AD, before exceeding 5,000 CSN.
Required actions
After the effective date of this AD, do not install or re-install onto any engine any HPC rotor stage 2-5 spool with a serial number listed in paragraph 4, Appendix A of GE SB No. GE90-100 S/B 72-0499, dated August 14, 2013, that exceeds 5,000 CSN.
Unsafe condition
Comply with this AD within the compliance times specified, unless already done.
Affected ADs
None.
Read the original on the Federal Register →
You just looked this one up by hand
TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.
- Bring your existing list in from a spreadsheet Paste the rows straight out of Excel. Headers like C/W Date and N/A are read for you.
- A copy that works when this does not One file. No internet, no login, no this software running. For the morning something has to be produced and the computer is not cooperating.
- $5 a month, or $50 a year Up to 50 aircraft on either.
Look round a real shop first Start free
The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.
The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1