TrackAD

Airworthiness directives › 2015-09-07

AD 2015-09-07 Airworthiness Directives; The Boeing Company Airplanes

Superseded. This directive was replaced by AD 2018-20-15. Work to the current one.
2015-05-01
2015-05-01
39-18153
FAA-2015-0936
Airframe
2018-20-15

Models named: 787. Read the applicability below — it usually turns on serial or part numbers too.

Applicability*9

This AD applies to all The Boeing Company Model 787 airplanes, certificated in any category.

Compliance

Comply with this AD within the compliance times specified, unless already done.

Required actions

At the latest of the times specified in paragraphs (g)(1), (g)(2), and (g)(3) of this AD, accomplish electrical power deactivation on the airplane, in accordance with step 2) in “DESIRED ACTION” of Boeing Multi Operator Message MOM-MOM-15-0248-01B, dated April 19, 2015; or Boeing Multi Operator Message MOM-MOM-15-0248-01B(R1), dated April 20, 2015. The main and auxiliary power unit (APU) batteries do not need to be disconnected when performing the electrical power deactivation. Repeat the electrical power deactivation thereafter at intervals not to exceed 120 days. (1) Within 120 days after the last electrical power deactivation in accordance with step 2) in “DESIRED ACTION” of Boeing Multi Operator Message MOM-MOM-15-0248-01B, dated April 19, 2015; or Boeing Multi Operator Message MOM-MOM-15-0248-01B(R1), dated April 20, 2015. (2) Within 120 days after the date of issuance of the original certificate of airworthiness or the date of issuance of the original export certificate of airworthiness. (3) Within 7 days after the effective date of this AD.

Unsafe condition

This AD was prompted by the determination that a Model 787 airplane that has been powered continuously for 248 days can lose all alternating current (AC) electrical power due to the generator control units (GCUs) simultaneously going into failsafe mode. This condition is caused by a software counter internal to the GCUs that will overflow after 248 days of continuous power. We are issuing this AD to prevent loss of all AC electrical power, which could result in loss of control of the airplane.

Affected ADs

None.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1