TrackAD

Airworthiness directives › 2016-03-07

AD 2016-03-07 Airworthiness Directives; Airbus Airplanes

2016-04-13
2016-03-09
39-18394
FAA-2015-3149
Airframe
—

Models named: A330-201, -202, -203, -223, -223F, -243, -243F, -301, -302, -303. Read the applicability below — it usually turns on serial or part numbers too.

Applicability*9

This AD applies to the airplanes, certificated in any category, identified in paragraphs (c)(1) and (c)(2) of this AD, all manufacturer serial numbers; except those on which a gaseous system for all oxygen generators is installed. (1) Airbus Model A330-201, -202, -203, -223, -223F, -243, -243F, -301, -302, -303, -321, -322, -323, -341, -342, and -343 airplanes. (2) Airbus Model A340-211, -212, -213, -311, -312, -313, -541, and -642 airplanes.

Compliance

Comply with this AD within the compliance times specified, unless already done.

Required actions

Within 30 days after the effective date of this AD: Inspect each passenger chemical oxygen generator to identify the date of manufacture (refer to figures 1 and 2 to paragraph (g) of this AD for the location of the date) of each passenger chemical oxygen generator having any part number (P/N) listed in paragraphs (g)(1) through (g)(6) of this AD, in accordance with the Instructions of Airbus Alert Operators Transmission (AOT) A35L007-14, Revision 01, June 17, 2015, including Appendix A, Revision 01, dated June 17, 2015. A review of airplane maintenance records is acceptable in lieu of this inspection if the date of manufacture of the generator can be conclusively determined from that review. (1) 117042-02 (15 minutes (min)—2 masks). (2) 117042-03 (15 min—3 masks). (3) 117042-04 (15 min—4 masks). (4) 117042-22 (22 min—2 masks). (5) 117042-23 (22 min—3 masks). (6) 117042-24 (22 min—4 masks). ER09MR16.000 ER09MR16.001

Unsafe condition

This AD was prompted by reports of premature aging of certain chemical oxygen generators in the passenger compartment that resulted in failure of the generators to activate. We are issuing this AD to prevent failure of the chemical oxygen generator to activate during an emergency situation, which could result in unavailability of oxygen and possible incapacitation of the occupants.

Affected ADs

None.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1