TrackAD

Airworthiness directives › 2022-15-02

AD 2022-15-02 Airworthiness Directives; Cameron Balloons Ltd. Burner Assemblies

2022-08-25
2022-07-21
—
—
Airframe
—

Applicability*9

(1) This AD applies to hot air balloons, certificated in any category, with a Cameron Balloons Ltd. Stratus double burner assembly part number (P/N) CB8720 or P/N CB8721 installed. (2) The affected burner assemblies may be installed on hot air balloon models including, but not limited to, those of the following design approval holders: (i) Aerostar International, Inc.; (ii) Ballonbau Worner GmbH; (iii) Balóny Kubíček spol. s.r.o.; (iv) Cameron Balloons Ltd.; (v) Eagle Balloons Corp.; (vi) JR Aerosports, Ltd (type certificate previously held by Sundance Balloons (US)); (vii) Lindstrand Balloons Ltd.; and (viii) Michael D. McGrath (type certificate subsequently transferred to Andrew Philip Richardson, Adams Aerostats LLC).

Compliance

Comply with this AD within the compliance times specified, unless already done.

Required actions

(1) For purposes of this AD, an “affected part A” is a Stratus double burner hanger P/N CB8504, Issue A, Issue B, or Issue C, except those installed on a Stratus double burner P/N CB8720 or P/N CB8721 with a doubler plate reinforcing the central part of the hanger bracket, as shown in figure 2 of Cameron Balloons Service Bulletin 28, Revision 3, dated February 3, 2021. (2) For purposes of this AD, an “affected part B” is a Stratus double burner P/N CB8720 or P/N CB8721 with a doubler plate reinforcing the central part of the hanger bracket, as shown in figure 2 of Cameron Balloons Service Bulletin 28, Revision 3, dated February 3, 2021. (3) For purposes of this AD, a “serviceable part” is a Stratus double burner hanger P/N CB8504, Issue D or later.

Unsafe condition

This AD was prompted by mandatory continuing airworthiness information (MCAI) originated by an aviation authority of another country to identify and correct an unsafe condition on an aviation product. The MCAI describes the unsafe condition as suspected fatigue cracking of the weld on affected burner hangers. The FAA is issuing this AD to prevent burners from separating from the balloon. The unsafe condition, if not addressed, could result in an uncontrolled cold descent and hard landing of the balloon.

Affected ADs

None.

Read the original on the Federal Register →

You just looked this one up by hand

TrackAD holds all 12,278 of them and matches them against the aircraft you actually look after — airframe, engine, propeller and appliances in one pass — then works out what falls due and when.

Look round a real shop first Start free

The demonstration shop is eleven real aircraft with a year of work behind them. No account needed.

The directive text above is reproduced from the Federal Register, a work of the United States government and in the public domain. The separation into applicability, compliance and required actions is TrackAD's.*1